I06 SEA WATER DISTILLATION.
8. Brine Discharge.
86. This outlet should be placed as far away as possible
from the feed inlet, and the brine should be taken from
the lower part of the casing, preferably up an internal
dip pipe to the level of the surface of the brine, where it
is then discharged into a receiver, and diluted and cooled
there. Or it can be allowed to flow away, or be blown
away, according to circumstances. All brine pipes should
be of ample size, as the furring of them soon takes place ;
if these pipes are made too small they will get choked.
9. The Water Level Gauge.
87. This gauge is usually placed on the evaporator
casing to indicate the level of the brine inside. When
the evaporator is working automatically at, or about,
atmospheric pressure, the brine automatically keeps at
a proper level, thus enabling the brine to overflow into
the receiver. This water gauge, therefore, indicates the
actual level of the brine when depressed by the slightly
varying pressure inside the casing, and is gradually forced
up the dip pipe, so that the level in the water gauge can
be read with the rise in the secondary pressure gauge on
the steam-room, the depression of the former being prac-
tically the same as the rise of the latter.
10. Test Cock.
88. This small cock is placed on some convenient part
of the evaporator shell, generally at about half the depth
of the brine. It is used in connection with the salinometer
for testing the strength—i.e., the salinity—of the brine.
In some cases the attendant in charge adopts this means.