A Practical Manual On Sea Water Distillation
With A Description Of The Necessary Machinery For The Process
Forfatter: Frank Normandy
År: 1909
Forlag: Charles Griffen & Co., LTD.
Sted: London
Sider: 244
UDK: 663.6
Søgning i bogen
Den bedste måde at søge i bogen er ved at downloade PDF'en og søge i den.
Derved får du fremhævet ordene visuelt direkte på billedet af siden.
Digitaliseret bog
Bogens tekst er maskinlæst, så der kan være en del fejl og mangler.
MULTIPLE DISTILLATION.
197
stated. The expression “ horse-power ” is sometimes
misunderstood.
56. The following Table N, giving a list of boilers
(Cornish and Lancashire type) suitable for sea water
evaporation, which has been found to answer well after
many years" use. The coal consumption is given
without multiple effect.
TABLE N .
Evaporation from Sea Water, in Practice (lbs. per Hour). Size of Boiler. Diam. x Length. Ft. In. X Ft. Heating Surface in Sq. Ft. Grate Surface for Coal in Sq. Ft. Coal Consumed per Hour, Lbs. Approx. Weight Boilers of 100 Lbs. W.P. Tons Avdp.
480 3’8 x 12 148 6’5 60 25
630 4-6 x 12 186 7-2 80 31
720 4-6 x 15 216 8'5 85 3-7
850 4-9 x 15 246 10 90 41
1,000 4'9 x 18 292 11 105 5
1,100 5'0 x 20 323 12 110 5'5
1,300 5'6 x 21 373 135 134 6-9
1,500 5'6 x 24 420 15 150 7'9
1,700 5-9 x 26 476 17 170 9-4
1,900 6 x 22 481 19 190 9-5
2,200 6’3 x 24 558 22 220 10-25 j
2,580 6'6 x 26 656 25 255 12'0 1
2,820 6’9 x 28 725 28 280 12'85
3,100 7 x 30 800 31 310 15-25
3,300 7-6 x 30 853 33 330 19-25
3,600 8 x 30 924 36 360 21-0
4,000 8-6 x 30 962 40 400 23'0
4,500 8'6 x 35 1,116 45 450 25-0
5. Boiler Fittings.
57. The usual fittings and mountings included are as
follows :—
(1) A pair of safety valves (usually weight and lever
type) fitted to the top of the steam dome.
(2) A steam valve in combination with the safety
valves (1).